VTF15666-1440 - Fil Transformer 110 VRMS to 6.3 V CT 5A 50/60Hz

Links


  • Order Code: VTF15666-1440.
  • Issue: 1.
  • Page Updated: 14 Jan 2011.
Picture:dpc12712.jpg

Specification

  • Primary: 110 VRMS 50/50Hz.
  • Output: 6.3v ct 5a.
  • Construction: Iron Laminated. Double insulated.
  • Treatment: Vacuum Varnish Impregnated.
  • Application: HT Anode and Heater supplies.
  • Range: Standard.

Mounting Arrangement

Picture:dpm12799.gif

Mechanical Dimensions

  • Size (SZ) = Patt29x1 FS.
  • Width (W) = 2 1/2 inch(64mm).
  • Depth (D) = 2 3/4 inch(70mm).
  • Height (H) = 3 1/16 inch(78mm).
  • Fix Centres (FWxFD) = 1 7/8 inch x 1 7/8 inch(48mm x 48mm).
  • Fix Size (FZ) = 3/16 inch(M4).
  • Weight (WT) = 2lb (0.9KG).

Circuit

Picture:dpe12740.gif Picture:dpe12582.gif Picture:dpe15662.gif

Connections

Function Connection
Neutral Blue wire
Live Brown wire
Heater A Blue+Blue marker wire (A)
Heater Centre Black+Blue marker wire
Heater B Blue+Red marker wire (B)

Connection Layout

Picture:dpm14626.gif Picture:dpm14578.gif

Below


Application Notes


  • Safety note: Warning. This part may be connected to high voltage. Disconnect then discharge for 5 minutes before working on circuit.